Coal Ash Storage Yard Liner and Leachate Control

Coal Ash Yard Liner · Pain points · Selection · Steps · Standards

3Selection items
6Steps
1FAQs
GBStandards cited
Summary: Coal ash yards generate fluoride- and sulfate-bearing leachate under rainfall. The liner system uses 1.5 mm HDPE membrane with composite drainage geonet for leachate collection and a cover-soil protection layer, plus perimeter flood diversion for clean-dirty separation.

Selection Table

Coal Ash Yard Liner selection
Position / functionRecommended materialStandard
Base primary liner1.5 mm smooth HDPEGB/T 17643-2025
Leachate drainageComposite geonet + collector pipesGB/T 40441-2021
Protection / filtration400 g/m2 staple geotextileGB/T 17638-2017

Installation Steps

  1. Compact and level the yard base
  2. Lay staple geotextile cushion
  3. Lay 1.5 mm membrane, double-seam weld and sample test
  4. Install geonet and leachate collectors to collection pond
  5. Cover soil protection and staged ash stacking
  6. Perimeter diversion ditches and monitoring wells

FAQ